Description
W&H Lyla Autoclave
W&H Lyla Autoclave. S Type Dental Steriliser.
Available in 17L and 22L chamber size
Simple to use colour touch screen – Easy to start a new cycle or schedule daily tests out of hours.
Combines outstanding reliability and traceability with exceptional speed.
S wrapped cycle times automatically adjust to fit the load;
0.5kg load 38 mins
2.0kg load 42 mins
4.0kg load 45 mins
S FAST CYCLE – 20 mins
USB data logger included for full audit compliance. No addidional software required to view information.
Remotely monitor using the W&H Steri App (free download) using the optional wi-fi kit.
Smart Upgrades
From S to B: Needs and requirements may change. Prepare yourself now with Lyla. With the Activation Code system, additional functions can be activated according to your needs. The “B cycle” feature upgrades Lyla simply and quick to a B type sterilizer according to EN 13060
B-Cycle 2.0kg load 45 mins
Rapid Eco B-Cycle 0.5kg 25 mins
Ergonomically designed. Adjustable feet to adapt depending on the workbench layout.
Easy to clean both inside and out.
Easy water fill using the integrated funnell. Or use automatic fill / drain function (8mm fitting, requires pressurised water source)
Thanks to the high level of reliability, it is reccomended an annual service is carried out, with a major service set to 4,000 cycles or 5 years.
In the last 12 months, W&H report an up time of 98.7% (up time equates to time when all sterilizers were working), which in the current market is above industry standard (industry standard 80-86%).
Lyla sterilization programs
Sterilization cycle | S Wrapped 134 | S Prion 134 | S Gentle 121 | S Unwrapped 134 | ||||
---|---|---|---|---|---|---|---|---|
Temperature: | 134 °C | 134 °C | 121 °C | 134 °C | ||||
Holding time (minutes): | 4 | 18′ 30” | 20′ 30” | 4 | ||||
Total cycle duration (minutes) including complete drying: |
Automatic from | Typical load |
Automatic from | Typical load |
Automatic from | Automatic from | Typical load |
|
Lyla 17 |
38′ to 45′
|
42′ |
52′ to 59′
|
56′ | 61′ to 64′ | 20′ to 26′ | 23′ | |
Lyla 22 (220 V) |
39′ to 46′
|
43′ |
53′ to 60′
|
57′ | 62′ to 66′ | 21′ to 27′ | 24′ | |
Lyla 22 (110 V) |
49′ to 56′
|
51′ |
63′ to 71′
|
65′ | 69′ to 73 | 28′ to 35′ | 30′ | |
Lyla 17/22 loads:
|
maximum solid 4 kg/typical 2 kg/maximum porous 0.5 kg
|
maximum 4 kg unwrapped
|
||||||
Lyla 17/22 container load: | maximum 4 kg | not applicable | ||||||
Test cycles: | Bowie and Dick/Vacuum test |
Lyla Sterilizer
Lyla 17 | Lyla 22 | |
---|---|---|
Type: | RIN-210 | RIN-210 |
Chamber size: | 17 l | 22 l |
Power supply: | 200–240 V AC; 50 Hz or 60 Hz; 10 A single phase | 200–240 V AC; 50 Hz or 60 Hz; 10 A single phase 100–125 V AC; 50 Hz/60 Hz; 12 A single phase |
Power consumption: | 2.0–2.4 kW | 220 V: 2.0–2.4 kW 110 V: 1.2–1.5 kW |
Overall dimension (width × height × depth): |
465 × 452 × 646 mm | |
Weight: | 40 kg | 42 kg |
Main / used water tanks: | 4.8/4.8 l | |
Working range: | 7 to 10 cycles | |
Usable space in chamber: (width × height × depth)¹: |
195 × 195 × 312 mm | 195 × 195 × 400 mm |
Connection types: | 1 USB port in the front (additional 1 in the rear as option), automatic water filling kit (optional) |
(1) Usable space is referred to standard rack configuration.
N°2017/745 | Medical Device Regulation |
2014/68/EU | Pressure Equipment Directive |
EN 13060 | Small steam sterilizer |
IEC 61326-1 | Electromagnetic compatibility |
IEC 61010-1 | Safety requirements sterilizer |
IEC 61010-2-040 | Specific requirements for steam sterilizer |
IEC 61770 | Electric appliances connected to the water mains |
Lyla 17
REF 19951150
Lyla 22
REF 19952150
Chamber size 22 litre
Items supplied with reversible rack, 3 aluminium trays, drain tube, tray holder, 8 GB USB drive, door opening tool, factory test